Article source:
Operating temperature: |
-40ºC to +85ºC (Some +100ºC versions are also available) |
Smoke emission: |
IEC 61034-1 & 2 |
HCl gas emission: |
IEC 60754-1 & 2 |
Flame retardant: | IEC 60332-3A ( IEC 60332-3-25 ) |
Fire resistant: |
IEC 60331- 3 hours @750ºC |
Approvals: |
Lloyds, DNV, ABS, or BV and Rina. Approvals may vary between manufacture brands. Please tell us at time of enquiry if you have a specific preference. |
XT marine cables offer a cost effective lightweight method to wiring in marine applications where mechanical protection is not required. Manufactured in accordance with the increasingly popular European standard IEC 60092-353.
Operating temperature: |
-40ºC to +85ºC (Some +100ºC versions are also available) |
Smoke emission: |
IEC 61034-1 & 2 |
HCl gas emission: |
IEC 60754-1 & 2 |
Flame retardant: |
IEC 60332-3A ( IEC 60332-3-25 ) |
Fire resistant: | IEC 60331- 3 hours @750ºC |
Approvals: |
Lloyds, DNV, or BV and Rina. Approvals may vary between manufacture brands. Please tell us at time of enquiry if you have a specific preference. |